Industrial Burners

DSE

  • ECOSTAR DSE series industrial burners with duoblock body structure are used in hot water boilers, steam boilers, hot oil boiler applications.
  • Natural gas, LPG, Heavy Oil, Light Oil, Biogas and special fuels can be used.
  • They have low flue gas emission values with their special body and combustion nozzle designs.
  • It can operate in harmony with different flame tube lengths in different combustion chambers and modernized applications.
  • According to the process needs, it is possible to control the liquid fuel lance with a movable structure in order to remove it from the hot area.
  • Able to operate at combustion air fan suitable for the process and at 200°C combustion air temperatures. (It is painted with high temperature resistant paint; product capacity varies in hot air operation.)
  • There is a secondary air control servo in the combustion chamber to intervene in flame diameter and length in line with the process needs.
  • A specially designed pilot ignition burner (ECOSTAR PAL Burner is used as standard in DSE series products) is available for ignition.
  • Energy saving with optional fan speed control,
  • High fire safety thanks to flame control with photocell.
  • Light oil filtering and pumping station is produced externally according to customer demand.
  • Light oil filtering, heating and pumping station are produced externally according to customer demand.
  • Remote management by connecting to PLC systems using BMS (Burner Management System) or software.
  • Provides easy installation and maintenance thanks to its service carrying shaft.

 
*If Low NOx is required for DSE series products, it must be specified at the order stage. The product extension must be selected as LE. (LE extension for LowNOx, SE extension for standard type )

Burner Type Burner Capacity Natural Gas Consumption Diesel Consumption Fuel Oil Consumption
  Max. MW Max. kcal/h Max. Nm³/h Max. kg/h Max. kg/h
DSE-65 28 24.080.000 2.919 2.361 2.495
* D B H C L1 L2 S1 S2 M1 M2 M3 M4 M5 M6 DN
DSE-65 EL Ø760 1550 1900 1125 935 990 Ø1190 Ø1050 562 1052 602 1092 642 1132
DSE-65 MS Ø760 1550 1900 1125 935 990 Ø1190 Ø1050 562 1052 602 1092 642 1132
DSE-65 N Ø760 1550 1900 1125 935 990 Ø1190 Ø1050 562 1052 602 1092 642 1132 DN150
DSE-65 NEL Ø760 1550 1900 1125 935 990 Ø1190 Ø1050 562 1052 602 1092 642 1132 DN150
DSE-65 NMS Ø760 1550 1900 1125 935 990 Ø1190 Ø1050 562 1052 602 1092 642 1132 DN150

*All dimensions in mm.

SPECIFICATION DSE 65
Electronic modulating control option
Mechanical proportional control option
Photocell flame control
Internal pilot ignition
ECOSTAR PAL pilot ignition burner
Pilot ignition gas valve
Air pressure switch
Options of operating with Gas / Heavy Oil / Light Oil / Gas-Light Oil / Gas-Heavy Oil
In liquid fuel products, high-pressure mechanic atomization lance or low-pressure air/steam-atomization lance
Ability to operate with hot combustion air*
Different mounting options
Serviceability without dismounting the burner from the boiler / service cover
Different flame tube length
Control via PLC with BMS or software
O2-CO combustion management system connection
Combustion air fan inverter connection
Fuel preparation stations (Gas line / Heavy Oil Station / Light Oil Station)
TSE EN Declaration of Conformity
CE Declaration of Conformity

: Not Included / N/A

: Optional

: Included / Available

ME: Mechanical Modulating

EL: Electronic Modulating