| Burner Type | Burner Capacity | Natural Gas Consumption | Diesel Consumption | Fuel Oil Consumption | |
|---|---|---|---|---|---|
| Max. MW | Max. kcal/h | Max. Nm³/h | Max. kg/h | Max. kg/h | |
| ECO-600.3 | 25,0 | 21.500.000 | 2606 | 2108 | 2228 |
| * | ØD | L | E | H | F | C | K | S1 | S2 | S3 | ØM1 | ØM2 | ØM3 | VL | DN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECO 600 OS 3 | Ø630 | 2155 | 810 | 1100 | 690 | 1450 | 950 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 475 | |
| ECO 600 OS 3 | Ø890 | 2550 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 870 | |
| ECO 600 KS 3 | Ø630 | 2155 | 810 | 1100 | 690 | 1450 | 950 | 600 | 650 | 708 | Ø740 | Ø792 | Ø860 | 475 | DN125 |
| ECO 600 KS 3 | Ø890 | 2550 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 870 | DN125 |
| ECO 600 G 3 | Ø698 | 2150 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 475 | DN125 |
| ECO 600 G 3 | Ø588 | 2550 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 870 | DN125 |
| ECO 600 OL 3 | Ø630 | 2155 | 810 | 1100 | 690 | 1450 | 950 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 475 | |
| ECO 600 OL 3 | Ø890 | 2550 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 870 | |
| ECO 600 KL 3 | Ø630 | 2155 | 810 | 1100 | 690 | 1450 | 950 | 600 | 650 | 708 | Ø740 | Ø792 | Ø860 | 475 | DN125 |
| ECO 600 KL 3 | Ø890 | 2550 | 810 | 1100 | 690 | 1000 | 500 | 600 | 660 | 708 | Ø740 | Ø792 | Ø860 | 870 | DN125 |
*All dimensions in mm.
| SPECIFICATIONS | ECO 600 ME | ECO 600 EL |
|---|---|---|
| Electronic modulating control option | ||
| Mechanical modulating control option | ||
| Photocell flame control | ||
| Internal pilot ignition | ||
| ECOSTAR PAL pilot ignition burner | ||
| Pilot ignition gas valve | ||
| Air pressure switch | ||
| Options of operating with Gas / Heavy Oil / Light Oil / Gas-Light Oil / Gas-Heavy Oil | ||
| In liquid fuel products, high-pressure mechanic atomization lance or low-pressure air/steam-atomization lance | ||
| Ability to operate with hot combustion air* | ||
| Different mounting options | ||
| Serviceability without dismounting the burner from the boiler /service cover | ||
| Different flame tube length | ||
| Control via PLC with BMS or software | ||
| O2-CO combustion management system connection | ||
| Combustion air fan inverter connection | ||
| Fuel preparation stations (Gas line/Heavy Oil Station/Light Oil Station) | ||
| TSE EN Declaration of Conformity | ||
| CE Declaration of Conformity |
: Not Included / N/A
: Optional
: Included / Available
ME: Mechanical Modulating
EL: Electronic Modulating