| Burner Type | Burner Capacity | Natural Gas Consumption | Diesel Consumption | Fuel Oil Consumption | |
|---|---|---|---|---|---|
| Max. MW | Max. kcal/h | Max. Nm³/h | Max. kg/h | Max. kg/h | |
| DIB-351 | 4,8 | 4.128.000 | 500 | 405 | 428 |
| * | ØD | L | H | F | C | K | S1 | S2 | S3 | ØM1 | ØM2 | ØM3 | VL | DN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DIB 351 EL 1 | Ø323 | 1700 | 900 | 550 | 1140 | 750 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 320 | |
| DIB 351 EL 1 | Ø520 | 2050 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 670 | |
| DIB 351 MS 1 | Ø323 | 1700 | 900 | 550 | 1140 | 750 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 320 | |
| DIB 351 MS 2 | Ø520 | 2050 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 670 | |
| DIB 351 N 1 | Ø346 | 1700 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 320 | DN80 |
| DIB 351 N 1 | Ø298 | 2050 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 670 | DN80 |
| DIB 351 NEL 1 | Ø323 | 1700 | 900 | 550 | 1140 | 750 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 320 | DN80 |
| DIB 351 NEL 1 | Ø520 | 2050 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 670 | DN80 |
| DIB 351 NMS 1 | Ø323 | 1700 | 900 | 550 | 1140 | 750 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 320 | DN80 |
| DIB 351 NMS 1 | Ø520 | 2050 | 900 | 550 | 740 | 350 | 350 | 410 | 450 | Ø430 | Ø480 | Ø550 | 670 | DN80 |
*All dimensions in mm.
| SPECIFICATIONS | DIB 351 ME | DIB 351 EL |
|---|---|---|
| Electronic modulating control option | ||
| Mechanical modulating control option | ||
| Photocell flame control | ||
| Internal pilot ignition | ||
| ECOSTAR PAL pilot ignition burner | ||
| Pilot ignition gas valve | ||
| Air pressure switch | ||
| Options of operating with Gas / Heavy Oil / Light Oil / Gas-Light Oil / Gas-Heavy Oil | ||
| In liquid fuel products, high-pressure mechanic atomization lance or low-pressure air/steam-atomization lance | ||
| Ability to operate with hot combustion air* | ||
| Different mounting options | ||
| Serviceability without dismounting the burner from the boiler / service cover | ||
| Different flame tube length | ||
| Control via PLC with BMS or software | ||
| O2-CO combustion management system connection | ||
| Combustion air fan inverter connection | ||
| Fuel preparation stations (Gas line/Heavy Oil Station/Light Oil Station) | ||
| TSE EN Declaration of Conformity | ||
| CE Declaration of Conformity |
: Not Included / N/A
: Optional
: Included / Available
ME: Mechanical Modulating
EL: Electronic Modulating